WebThe Construction Site Safety Technician (CSST) course is designed for industry safety professionals, company safety officers, current site safety coordinators or foremen … WebApr 19, 2015 · The bonding conductor shall beinstalled and protected in accordance with the National Electrical Code, NFPA 70, (NEC) and Canadian Electrical Code …
Csst shall be listed in accordance with
Did you know?
WebPiping Category 3: NC Fuel and Gas Code § 310.1.1 Exception: CSST with an arc-resistant jacket listed by an approved agency for installation without the direct bonding, as prescribed in this section, shall be installed in accordance with Section 310.1 and the manufacturer’s installation instructions. WebJan 13, 2010 · Here's what NYS requires: “G2411.2 (310.2) Gas pipe bonding - systems that contain CSST.A gas piping system that contains any corrugated stainless steel tubing (CSST) shall be electrically continuous and shall be bonded to the electrical service grounding electrode system at the point where the gas service enters the building or …
WebSep 20, 2001 · "5.6.3.4.1C orrugated stainless steel tubing (CSST) shall be listed in accordance with ANSI LC 1/CSA 6.26, Fuel Gas Piping Systems Using Corrugated … WebCSST listed with an arc resistant jacket or coating system in accordance with CSA LC 1 shall be electrically continuous and bonded to an effective ground fault current path. Where any CSST component of a piping system does not have an arc-resistant jacket or coating system, the bonding requirements of Section 1211.2 shall apply. Arc-resistant jacketed …
Web“Section 310.1.2 Arc-resistant CSST. This section applies to corrugated stainless steel tubing (CSST) that is listed with an arc-resistant jacket or coating system in accordance with ANSI LC 1/CSA 6.26. The CSST shall be electrically continuous and bonded to an effective ground fault current path. Where any CSST component of http://ctbuildingofficial.org/node/229
Web(1) Other than Corrugated Stainless Steel Tubing (CSST). The bonding jumper(s) shall be sized in accordance with Table E3908.12, using the rating of the circuit capable of energizing the piping. The equipment grounding conductor for the circuit that is capable of energizing the piping shall be permitted to serve as the bonding means. (2) CSST.
can i eat chocolate in morningWebCSST gas piping systems shall be bonded to the electrical-service grounding electrode system. The bonding jumper shall connect to metal pipe or fitting between the point of delivery and the first downstream CSST fitting. ... Pipe sizing tables or sizing equations in accordance with Equations 24-3 or 24-4. The sizing table included in a listed ... fitted infant car seat cover patternWebSep 12, 2013 · The bonding jumper shall connect to a metallic pipe or fitting between the point of delivery and the first downstream CSST fitting. The bonding jumper shall be not smaller than 6 AWG copper wire or equivalent. Gas piping systems that contain one or more segments of CSST shall be bonded in accordance with this section. fitted indoor car coverWebThe bonding jumper shall connect to a metallic pipe or fitting between the point of delivery and the first downstream CSST fitting. The bonding jumper shall be not smaller than 6 AWG copper wire or equivalent. Gas piping systems that contain one or more segments of CSST shall be bonded in accordance with this section. TABLE G2413.4(5) [402.4(15)] fitted insertion lossWebCSST: Certified Site Surveillance Technician: CSST: China Security & Surveillance Technology, Inc. CSST: Colorado Springs Swim Team (Colorado) CSST: Council for … fitted hybrid diaper overnightWebA gas piping system that contains any CSST shall be electrically continuous and shall be directly bonded to the electrical service grounding electrode system. No portion of the gas piping system shall be used as or considered to be a grounding electrode or a grounding electrode conductor. CSST shall be installed and bonded in accordance with Section … can i eat chocolate on a low residue dietWebJul 6, 2024 · 7.12.2.1. The bonding jumper shall connect to a metallic pipe, pipe fitting, or CSST fitting. 7.12.2.2. The bonding jumper shall not be smaller than 6 AWG copper wire or equivalent. 7.12.2.3*. The length of the jumper between the connection to the gas piping system and the grounding electrode system shall not exceed 75 ft (22 m). can i eat chocolate in high bp